Buy these from the leading suppliers and … Bellows Pipettes - 1/4" Rigid Tubing (20 mL Bellows), Bellows Pipettes - 5/32" Flexible Tubing (20 mL Bellows), L2000® PCB Surface Wipes and Test Reagents, HydroSCOUT® Analyzer System - Percent Range Oil, PetroFLAG® 1mL Pipettor - for High Range Option, PetroFLAG® Analyzer System for TPH in Soil, PetroFLAG® Calibration Standards (1000 ppm), HydroSCOUT® Analyzer System - Paints & Coatings, HydroSCOUT® Analyzer System - PPM Range Oil. Furan measures the degradation of cellulose paper. This oil sample kit is an accurate test of transformer fluids for the presence of PCBs. Each pipette has 12” tubing (choose flexible or rigid) connected to a bellows reservoir that can hold up to 20 ml of transformer oil. GST No. Jul 8, 2020 - High quality ISO 3679 ISO 3680 ASTM D3278 ASTM D3828 Flash Point Equipment from China, China's leading ISO 3679 flash point equipment product, with strict quality control ISO 3680 flash point equipment factories, producing high … Supply Of Karl Fisher Testing Kit Of Transformer Oil Water Content (ppm) At Power Transformer Repair Unit At Kalamassery As Per The Detailed Technical Specification In Ksebl Tender Tendersinfo provides online tenders information about all kinds of government tenders, global tenders, govt tenders and contracts. Andax Clor-N-Oil Kit - 50 ppm. Andax Clor-N-Oil Kit - 50 ppm. Dexsil's first PCB (polychlorinated biphenyl) test kit, Clor-N-Oil 50, was introduced in 1983 and has become the standard for quick PCB screening of transformer oil in the field. Moisture content in oil lowers the insulating system dielectric strength and allows flashover that can damage a transformer. Over the past five decades we have generated millions of test results from thousands of high-voltage units, and we process samples from transformer owners across the country. few parts per million. In this kit, oil is kept in a pot in which one pair of electrodes are fixed with a gap of 2.5 mm (in some kit it 4mm) between them. The same applies to transformer oils and other electrical distribution equipment. The sampling kits also include a convenient postage paid mailer for sending collected wipe samples to Dexsil’s lab for analysis. Designed to be used in the field, the PCB Oil Test Kit is a fast, accurate method to test electrical insulating fluids for the presence of PCB. The DOMINO USS is a portable system that connects quickly and easily to transformer valves or … Test Kit PCB 50ppm (Transformer Oil Testing) CLOR-N-OIL. This field test kit has become the standard in testing for PCBs in insulating fluid. Buy test meters, test equipment and accessories at discount prices! Manufacturer of Transformer Oil Test Kit [BDV] is engaged in the manufacturing of the Oil Test Kit, which are known as the microprocessor based test equipment. 30 ml or 50 ml DGA Glass Syringes, Nylon Valve, Side Plugs, Tygon tubing, Luer Connector, and a Foam Padded Syringe Carrying Cases are used for collecting oil samples from the power transformer. SHEPHERD make fully Automatic Insulating Oil Tester. The service has been developed specifically to apply to all types and sizes of transformers filled with mineral or silicon insulating oil. D1533. PT Hyprowira Adhitama Laboratory can currently conduct a screening test to detect the presence of PCBs in transformer oil at a limit of 2 ppm, using: SM-TCPs SM-TCPsLC Instruments - Sea Marconi Potentiometric Test Kit at low concentrations - Total Chlorine and PCBs screening in minerals oil from 0.5 to 10 ppm of SEA Marconi equivalent - Patented Method PCB - Total … These Clor-N-Oil kits are very useful for testing for PCBs in the field. ater content in transformer oil in parts per million (ppm) is a familiar concept to most in our industry, and limits of 30 to 35 ppm are generally referenced. Several improvements have been made to the Clor-NOil kits since their introduction including the addition of a "disposal ampule" which allows the … Ask our expert. What is Transformer Oil? It owns advantages of high testing accuracy, good repeatability... Read More Get Best Price Aroclor 1242 contains the least amount of chlorine (42% by weight) of the Aroclors found in electrical insulating fluids. Andax Clor-N-Oil Kit - 50 ppm. Routine testing of transformer insulating oil is an essential maintenance function that ensures a safe working environment and helps eliminate the possibility of disrupted production resulting from a transformer … Further reaction of these acids with the bulk oil can result in sludge … They cannot be used to determine PCB contamination of other types of used oils (i.e. Overview Technical. Aroclor 1242 contains the least amount of chlorine (42% by weight) of the Aroclors found in electrical insulating fluids. The PCB Test Kit is available for testing transformer oil at three different action levels: 20 ppm, 50 ppm and 500 ppm. Academic Calendar; College Documentation DRIVEN BY DATA, POWERED … The L2000DXT is an electro-chemical test method that employs the same basic chemical extraction technology as the Clor-N-Oil and Clor-N-Soil kit test kits, but rather than a fixed end-point color change, results are calculated by the L2000DXT computer and displayed in ppm (wipes samples; ug/100cm2). oil water content testing ppm meter transformer oil moisture content testing kit, US $ 1000 - 2600 / Set, Hebei, China, HUAZHENG, HZWS-X2.Source from Huazheng Electric Manufacturing (Baoding) Co., Ltd. on Alibaba.com. They are designed to eliminate any chance of cross-contamination and make it easy to follow EPA sampling protocol. Clor-N-Oil is available for testing transformer oil at three different action levels; 20 ppm, 50 ppm and 500 ppm. Premeasured reagents are sealed in glass ampules for safe, fast, consistent and accurate results. 19AUNPS6228F1Z4. Instrument is fully compliant with ASTM D3612 and IEC 60567 standards. There is no need to transport samples to laboratories anymore - simply put a sample and press test button. Some manufacturers require a Minimum Advertised Price (MAP). In order to obtain a representative transformer oil sample from the body of the oil a standard approach, well-trained operatives and a sampling adapter to ensure a steady flow of oil are essential. Oxidation products are usually acidic in nature and result in an increase in acid number. Basically that means we show the manufacturer's price and you negotiate your best price with us. Our transformer oil testing kit is a PCB oil analysis kit designed to be used in the field. Regular sampling and testing of insulation oil taken from transformers is a valuable technique in a preventative maintenance pr ogram. That interaction with you, the customer, enables us to offer you an even lower price for this product. The test kit will have provision for automatic switching off of the supply voltage within 0.02 second. Now slowly rising voltage is … Pocket sized for convenience. Related Products of the Clor-N-Oil® PCB Test Kit. WATER CONTENT Test Method IEC 814 Water, in … PCB’s: Polychlorinated Biphenyls. Thanks for clicking. ASTM D877 ASTM D1816 IEC156 Transformer Oil Test Kit Model: BDV-II BDV-II Transformer Oil Test Kit: BDV-II ASTM D877 IEC156 Transformer Oil Test Kit is developed according to the national standard IEC156 ... Read More Get Best Price. By calibrating these oil test kits using Aroclor 1242, the user obtains the most conservative results. Pocket sized for convenience. Contact Us: Send E-mail Call 7971385473 32% Response Rate. Each Clor-N-Oil® PCB Oil Test Kit contains everything you need to perform the PCB Test Kit in less than 5 minutes. Screening transformer oil with Oil Test Kit can eliminate non-PCB fluids from costly laboratory analysis and allows a greater number of oil samples to be tested at less cost. 2020-11-09 12:00:56. Transformer Oil Analysis Service. ₹ 19,500. This early warning system can allow maintenance management to identify maintenance priorities, plan work assignment schedules, arrange for outside service, and order necessary parts and materials. Test results available within 5 minutes. Test results available within 5 minutes. Our experienced personnel, utilizing new and state of the art equipment, provide a broad range of fluid tests and diagnostic interpretation to maintain and extend the life of your transformers and other electrical equipment. Primary Current Injection Test Set. Manufacturer of Oil Testing Kit - NABL Calibration of Oil Test Kit BDV, Oil Acidity Test Kit, 0-80 kV Manual/Motorized Oil BDV Test Kit and transformer oil filter machine offered by Monarch Controls, Bengaluru, Karnataka. Originally used for their excellent electrical characteristics and not being flammable. Mild Steel Transformer Oil Insulation Test Set. oil water content testing ppm meter transformer oil moisture content testing kit, US $ 1000 - 2600 / Set, Hebei, China, HUAZHENG, HZWS-X2.Source from Huazheng Electric Manufacturing (Baoding) Co., Ltd. on Alibaba.com. In the past, there used to be a British Standard which gave a range of colours from 1 … Oil Moisture Content Testing Kit, Karl Fischer Moisture Meter, Oil Water Content Tester manufacturer / supplier in China, offering Ce Certified Ppm Moisture Content Analysis Transformer Oil Testing Kit, Mobile Dielectric Oil Purifier Machine with Enclosure (ZYD-M-30), Automatic Water Content Measuring Equipment for Petroleum Products (TP-2100) and so on. to monitor the quality of the oil & determine the operation as well as the condition of the equipment's. The field portable L2000DXT system is easy to use and offers an analysis range of 3-2000 ppm (wipes: ug/100 cm2). Contact Now. ₹ 35,000. Call Us-+91-9457657942, +91-9917344428. When the Oil Test Kit turns purple, you can be assured your oil sample is below the action level. In addition to the original 50 ppm kit, there are two other test options available: 20 ppm and 500 ppm. Clor-N-Oil is available for testing transformer oil at three different action levels; 20 ppm, 50 ppm and 500 ppm. It can be used on water-soluble cutting fluids, sump and bilge water, antifreeze or any fluid that contains greater than 70 % water. About Us. Oil Acidity Test Kit, Transformer Oil Test Kit, Oil Acid Value Tester manufacturer / supplier in China, offering Fair Trade Oil Test Equipment Transformer Oil Acidity Test Kit, High Quality Automatic Testing Machine Transformer Winding DC Resistance Tester, Portable Coulometric Ppm Karl Fischer Moisture Meter for Transformer Oil and so on. Now slowly rising voltage is … The PCB Test Kit is available for testing transformer oil at three different action levels: 20 ppm, 50 ppm and 500 ppm. In addition to the original 50 ppm kit, tests for 20, and 500 ppm are also available. If a proactive approach is adopted based on the condition of the transformer oil, the life of the transformer can be extended. Our Transformer Oil Testing Set, Gas Dew Point Detection Instrument & Trace Water Content Tester, Transformer Oil Tester such as Dielectric Strength Tester, Capacity and Loss Tester have the features with high quility. Number : 42544148: Tender Number : 2020_UPTCL_513006_5 Tender Prod. How to use our Oil Analysis Service. Each pocket-sized PCB Test Kit contains everything necessary to perform the test in less than 5 minutes. Speak your question. Alibaba.com offers efficient and precise automatic transformer oil acidity test kit for all types of machinery, bacteria, seeds, etc. Rcsm Mahavidhalay | Home; About us. Electric Oil Withstand Voltage Tester, Oil Dielectric Strength Tester. One of most important transformer oil test is dissolved gas test. BDV Test of Transformer Oil; Impedance Voltage Test; Vector Group Test; Earth Resistance Test; CT Testing (Knee point Voltage Test & Primary Injection) Due Point Test (Doble Make Kit) Moisture Content in Oil(PPM) (Doble Make Kit) Moisture Content in SF6 Gas (Doble Make Kit) CT ,PT & Power Analyzer for Loss Measurement(Yokohama)